Causes and troubleshooting of general failures of helical gear reducer motors

发布时间:2018-05-31 14:38浏览 次数:

malfunction Possible Causes Approach
Reducer overheating 1) Overload
2) Insufficient or excessive lubricating oil
1)检查实际负荷,调整到规定值上或更换较大功率的Reducer
2) Use oil in accordance with the prescribed amount of oil
Abnormal and stable running noise 1) Rotation/grinding noise, bearing damage
2) Knocking noise, irregular meshing
1) Check the oil
2) Contact the user service agency
Abnormal and unstable running noise Oil contamination or insufficient oil Change the oil or refuel to the specified value
Ventilator leaks 1) Too much oil
2) The ventilator is not installed correctly
1) Correct the oil level
2) Install the ventilator correctly
Oil spill Seal damage Contact the customer service agency
The output shaft does not rotate when the motor is rotating Destruction of reducer coupling Send for overhaul
Note:
If you need the help of our company's user service department, please:
1. Explain the data of the nameplate in detail
2. Explain in detail the type and extent of the failure
3. Explain the time and circumstances of the failure in detail
4. Explain the possible reasons in detail