Test method for temperature increase of cycloidal pinwheel reducer

发布时间:2018-05-24 10:40浏览 次数:

XNUMX. Environmental conditions
1 The temperature rise of the cycloid reducer should be measured indoors that are not affected by the external temperature. The indoor ambient temperature should be within the range of 5-40°C. Should the indoor air circulate freely? Forced circulation is not allowed.
2. Temperature measurement point
测温点应选择在温度计能够接触到摆线针轮减速机润滑油的位置。
XNUMX. Thermometer
The graduation value is 0.5°C.
Three, determination method
1. Determination of working temperature
被测减速机温升的测定,通常与减速机的承载能力及传动效率测定同时进行,也可单独进行,被测减速机在符合规定时,读取减速机在额定转速、额定输入功率下的工作温度。
2. Measurement of ambient temperature
在距被测摆线针轮减速机表面1.5m 处放置温度计,温度计测点距地面的高度与减速机轴心线等高,温度计的放置应不受外来辐射热与气流的影响,环境温度数值的读取与工作温度数值的读取应同时进行。
Four, temperature rise calculation
The temperature rise is calculated as follows: 
Where: Δt——temperature rise of reducer, ℃
摆线针轮减速机在额定转速、额定输入功率下的工作温度,℃
环境温度,℃。 t2—— t1—— Δt=t1–t2